ENERJOY I Specifications
                  Bid Specifications:
                    The ENERJOY® radiant heating panel shall be constructed of  insulated Solid State Heating element. The element shall be backed with  one-inch thick, high density, odorless fiberglass board, faced with a white  finely textured aluminum face and framed in aluminum. Panels shall reach the  full surface temperature in five minutes. Radiant output shall be 95% of input  energy. Panels shall be listed under UL Standard 2021 – Fixed and Location-Dedicated  Electric Room Heaters. Panel shall meet or exceed FHA/HUD Minimum Property  Standards.
                  Contents:
                  
                  
                  
                      
                      
         
             
                  
                  
                  
                  
                  
                  INSTALLATION of the multi-sized panels is as easy as an electric  light fixture – mounted on the surface, flush, placed in a suspended ceiling  grid, or freely suspended. Painting, overspraying with water base acoustical  material, or framing creates the desired aesthetic effect. Do no operate until  dry.
                    Penetrable Surface Mounting (sheetrock) (Fig. 1)-(check for bag of hole plugs) 
                  
                    - Insure adequate clearance hole in center for module connection box.
 
                    - Install connection box to back of module using the prepositioned       screws.
 
                    - Connect the power supply conductors to the module leads in the       connection box.
 
                    - Position on ceiling, holding module in place.
 
                    - Punch or drill holes into the ceiling to provide a hole for the       screw/anchor assembly, or mark holes for drill.  The frame mounting       holes are designed to accept #6 -1 ¾” Pan head screws.
 
                    - Insert installer provided screw/anchor assembly into the ceiling,       and tighten into place. Insert plastic caps to close       frame screw holes.
 
                  
                  T-Bar Mounting (Fig. 2)
 
                  
                    - Install connection box to back of module using the two       prepositioned screws.
 
                    - Lay the module carefully onto the T-Bar grid and secure with       installer provided hold-down clips if necessary. 
 
                    - Connect the power supply conductors to the module leads in the       module connection box. 
 
                  
                  
This is a description of a major benefit of using the product. 
                      Inpenetrable Surface Mounting - RPD model (Concrete) (Fig. 3)
                      
                      
                  
                    - Assemble Wiremold junction box and rear plate and attach to the       side of the panel frame with the provided hardware. 
 
                    - Position panel and junction box assembly onto ceiling to mark the       location of the panel and junction box mounting holes.
 
                    - Drill holes (3-1/16" dia., 1-1/4" deep) at each mark and       insert anchors into drilled holes.
 
                    - Hold the panel and junction box assembly to the ceiling; insert       screw completely through large frame hole and screw securely through small       frame hole into anchor.
 
                    - Bring Wiremold raceway through appropriate knockout of panel       junction box.
 
                    - Connect the power supply conductors to the panel leads: Attach the       grounding conductor to the provided ground clip.
 
                  
                  
                  Each panel has been individually checked at the factory. However each panel  should be field checked by measuring cold resistance for confirmation with  label wattage. After panel installation, the entire circuit should be tested,  to check the on-sight electrical work. Two methods of testing will be discussed  in the following paragraphs.
                      Full Power Available - Apply rated voltage to the heater load  circuit. Branch loads are to be read with a suitable amp meter. The amp meter  value should be the same as that calculated for the heating load and, if the  values agree, all panels are operating. If the values do not agree,  installation should be re-checked. For physical check without a meter, it is  only necessary to feel the panels. If they are warm but can only be touched for  a few seconds, they are working.
                      Without Power Available - This check of the panel installation  requires the use and knowledge of an ohmmeter. A resistance measurement is  taken at the load circuit, with all other circuits isolated. This will give the  total resistance of the heater load. Knowing the total heater load of the panel  in watts and the heater rated voltage, a simple calculation will give the same  values as that read on the ohm meter. (The same test procedure applies of an  individual panel)  Example: For a branch circuit of 1500 watts and panel  rated voltage of 240, the resistance will be 38.4 ohms:
                      
                  
                  
                  
                    
                      All    sizes also available in 208 and 277 volt     (other sizes    and wattages available)  | 
                    
                    
                      Model No.  | 
                      Voltage  | 
                      Watts  | 
                      BTUH  | 
                      Amperage  | 
                      Size  | 
                      Weight(lbs.)  | 
                    
                    
                      Under Desk Heaters  | 
                    
                    
                      12UDH-4  | 
                      120  | 
                      100  | 
                      341  | 
                      0.8  | 
                      11¾" x    23¾" x 1 1/8"  | 
                      3  | 
                    
                    
                      22UDH-4  | 
                      120  | 
                      200  | 
                      683  | 
                      1.7  | 
                      23¾" x 23¾ x 1    1/8"  | 
                      3  | 
                    
                    
                      Radiant    Ceiling Panels                                      NOTE: All Panel Frames have mounting holes except T-BAR  | 
                    
                    
                      22RCL-2  | 
                      240  | 
                      200  | 
                      682  | 
                      0.8  | 
                      23¾" x 23¾ x 1    1/8"  | 
                      6  | 
                    
                    
                      22RCL-4  | 
                      120  | 
                      200  | 
                      682  | 
                      1.7  | 
                      23¾" x 23¾ x 1    1/8"  | 
                      6  | 
                    
                    
                      22RCL-2or4TBar  | 
                      120or240  | 
                      200  | 
                      682  | 
                      0.8 or 1.7  | 
                      23¾" x 23¾ x 1    1/8"  | 
                      6  | 
                    
                    
                      23RCL-2  | 
                      240  | 
                      300  | 
                      1024  | 
                      1.3  | 
                      23¾" x 35¾ x 1    1/8"  | 
                      8  | 
                    
                    
                      23RCL-4  | 
                      120  | 
                      300  | 
                      1024  | 
                      2.5  | 
                      23¾" x 35¾ x 1    1/8"  | 
                      8  | 
                    
                    
                      23RCH-2  | 
                      240  | 
                      375  | 
                      1280  | 
                      1.6  | 
                      23¾" x 35¾ x 1    1/8"  | 
                      8  | 
                    
                    
                      23RCH-4  | 
                      120  | 
                      375  | 
                      1280  | 
                      3.1  | 
                      23¾" x 35¾ x 1    1/8"  | 
                      8  | 
                    
                    
                      24RCL-2  | 
                      240  | 
                      400  | 
                      1365  | 
                      1.7  | 
                      23¾" x 47¾ x 1    1/8"  | 
                      11  | 
                    
                    
                      24RCL-4  | 
                      120  | 
                      400  | 
                      1365  | 
                      3.3  | 
                      23¾" x 47¾ x    1"  | 
                      11  | 
                    
                    
                      24RCL-2or4TBar  | 
                      120or240  | 
                      400  | 
                      1365  | 
                      1.7 or 3.3  | 
                      23¾" x 47¾ x    1"  | 
                      11  | 
                    
                    
                      24RCH-2   | 
                      240  | 
                      500  | 
                      1706  | 
                      2.1   | 
                      23¾" x 47¾ x 1    1/8"  | 
                      11  | 
                    
                    
                      24RCH-4  | 
                      120   | 
                      500  | 
                      1706  | 
                      4.2  | 
                      23¾" x 47¾ x 1    1/8"  | 
                      11  | 
                    
                    
                      25RCL-2  | 
                      240  | 
                      500  | 
                      1706  | 
                      2.1  | 
                      23¾" x 59¾ x 1    1/8"  | 
                      13  | 
                    
                    
                      25RCL-4  | 
                      120  | 
                      500  | 
                      1706  | 
                      4.2  | 
                      23¾" x 59¾ x 1    1/8"  | 
                      13  | 
                    
                    
                      25RCH-2  | 
                      240  | 
                      625  | 
                      2133  | 
                      2.6  | 
                      23¾" x 59¾ x 1    1/8"  | 
                      13  | 
                    
                    
                      25RCH-4  | 
                      120  | 
                      625  | 
                      2133  | 
                      5.2  | 
                      23¾" x 59¾ x 1    1/8"  | 
                      13  | 
                    
                    
                      26RCL-2  | 
                      240  | 
                      600  | 
                      2047  | 
                      2.5  | 
                      23¾" x 68¾ x 1    1/8"  | 
                      15  | 
                    
                    
                      26RCH-2  | 
                      240  | 
                      750  | 
                      2560  | 
                      3.1  | 
                      23¾" x 68¾ x 1    1/8"  | 
                      15  | 
                    
                    
                      26RCL-4  | 
                      120  | 
                      600  | 
                      2047  | 
                      5.0  | 
                      23¾" x 68¾ x 1    1/8"  | 
                      15  | 
                    
                    
                      26RCH-4  | 
                      120  | 
                      750  | 
                      2047  | 
                      6.3  | 
                      23¾" x 68¾ x 1    1/8"  | 
                      15  | 
                    
                    
                      27RCL-2  | 
                      240  | 
                      700  | 
                      2388  | 
                      2.9  | 
                      23¾" x 83¾ x 1    1/8"  | 
                      17  | 
                    
                    
                      27RCL-4  | 
                      120  | 
                      700  | 
                      2388  | 
                      5.8  | 
                      23¾" x 83¾ x 1    1/8"  | 
                      17  | 
                    
                    
                      27RCH-2  | 
                      240  | 
                      875  | 
                      2986  | 
                      3.7  | 
                      23¾" x 83¾ x 1    1/8"  | 
                      17  | 
                    
                    
                      27RCH-4  | 
                      120  | 
                      875  | 
                      2986  | 
                      7.3  | 
                      23¾" x 83¾ x 1    1/8"  | 
                      17  | 
                    
                    
                      28RCL-2  | 
                      240  | 
                      800  | 
                      2730  | 
                      3.3  | 
                      23¾" x 95¾ x 1    1/8"  | 
                      19  | 
                    
                    
                      28RCH-2  | 
                      240  | 
                      1000  | 
                      3413  | 
                      4.2  | 
                      23¾" x 95¾ x 1    1/8"  | 
                      19  | 
                    
                    
                      28RCL-4  | 
                      120  | 
                      800  | 
                      2730  | 
                      6.7  | 
                      23¾" x 95¾ x 1    1/8"  | 
                      19  | 
                    
                    
                      Bathroom    Fan/light/nightlight package - complete: includes Decora switch/cover &    thermostat.  Also available in ‘H’    higher wattage models.  | 
                    
                    
                      22RCLFL-2    or 4  | 
                      240    or 120  | 
                      200  | 
                      682  | 
                      0.8/1.7  | 
                      23¾"    x 35¾" x 1 1/8"  | 
                      7+25  | 
                    
                    
                      23RCLFL-2    or 4  | 
                      240    or 120  | 
                      300  | 
                      1024  | 
                      1.2/2.5  | 
                      23¾"    x 47¾" x 1 1/8"  | 
                      9+25  | 
                    
                    
                      24RCLFL-2 or 4  | 
                      240 or 120  | 
                      400  | 
                      1365  | 
                      1.7/3.3  | 
                      23¾" x    59¾" x 1 1/8"  | 
                      12+25  | 
                    
                    
                      25RCLFL-2 or 4  | 
                      240 or 120  | 
                      500  | 
                      1720  | 
                      2.1/4.2  | 
                      23¾" x    68¾" x 1 1/8"  | 
                      14+25  | 
                    
                    
                      26RCLFL-2 or 4  | 
                      240 or 120  | 
                      600  | 
                      2082  | 
                      2.5/5.0  | 
                      23¾" x    83¾" x 1 1/8"  | 
                      17+25  | 
                    
                    
                      27RCLFL-2 or 4  | 
                      240 or 120  | 
                      700  | 
                      2388  | 
                      2.9/5.8  | 
                      23¾" x    95¾" x 1 1/8"  | 
                      19+25  |